Solution

Refrigeration

Autonomous Cooling Efficiency

Autonomous compressor dispatch adapting to load changes, keeping cooling efficiency close to the optimal COP curve — significantly reducing refrigeration system operating energy.

8~15%
Cooling Energy Reduction
0.3+
COP Improvement
40%+
O&M Labor Savings

Pain Points

Industry Pain Points

01

Dramatic Load Changes

Cooling load varies dynamically with outdoor temperature and usage scenarios — fixed control strategies cannot maintain efficient operation.

02

Complex Multi-device Group Control

Compressors, cooling towers, pumps coordinated operation — start/stop and load allocation rely on manual experience.

03

Efficiency Deviation from Optimum

Systems often operate at non-optimal working points — actual COP significantly deviates from theoretical optimum.

04

High O&M Costs

Refrigeration systems run 24/7 — night and holiday staffing costs are high with inconsistent operational quality.

05

Hard to Quantify Savings Potential

Lacking global energy efficiency analysis — unable to accurately assess subsystem savings potential and optimization direction.

06

Carbon Emission Pressure

Under dual-carbon policies, refrigeration systems as high-energy consumers face continuous requirements for energy saving and carbon reduction.

Our Solution

Our Approach

RL-driven autonomous decision-making for refrigeration systems — keeping compressor clusters operating near the optimal efficiency curve.

Intelligent Compressor Dispatch MOD_01

RL-based autonomous compressor start/stop and load allocation decisions — real-time optimization based on ambient temperature, load changes, and equipment status.

Cooling System COP Optimization MOD_02

Intelligent adjustment of chilled water temperature, cooling tower fan speed, and other parameters — maximizing system COP while meeting cooling demand.

Load Prediction & Pre-scheduling MOD_03

Based on historical data and environmental forecasts, proactively plan equipment states — avoiding energy waste and equipment wear from frequent start/stop cycles.

Efficiency Monitoring & Analysis MOD_04

Real-time monitoring of system COP, per-device efficiency, and other key metrics — automatically generating efficiency analysis reports to support O&M decisions.

Value Delivered

Engineering & Business Value

8~15%

Cooling Energy Reduction

0.3+

COP Improvement

40%+

O&M Labor Savings

7 Days

Rapid Deployment Cycle

Get Started

Redefine Refrigeration Energy Standards

Keep cooling efficiency near the optimal curve — achieving true autonomous energy saving.